The RATO RT50YB80-3.8Q is a 2-inch twin-impeller high-lift pump powered by a 7 hp R210 four-stroke engine.

Product overview

This twin-impeller high-pressure pump is suited to supported applications including irrigation, fire security, orchard water supply, cleaning and long-distance water transfer. A full protective frame surrounds the pump and engine.

Supported specifications

Model: RT50YB80-3.8Q
Engine: R210, 7 hp, single-cylinder four-stroke OHV
Starting system: Recoil
Displacement: 212 cc
Net power: 4.4 kW at 3,600 rpm
Net torque: 12 N·m at 2,500 rpm
Pump set: 2-inch high-lift pump
Suction port: 50 mm (2 inches)
Discharge ports: 1 × 1.5 inches and 2 × 1 inch
Maximum suction head: 7 m
Maximum total head: 80 m
Maximum capacity: 16 m³/h (266 L/min)
Dimensions: 500 × 395 × 446 mm
Net weight: 29.5 kg


What's in the box

  • Model

    RT50YB80-3.8Q
  • Impeller

    Twin
  • Engine

    RATO R210, 7 hp
  • Engine Type

    Single-cylinder four-stroke OHV
  • Starting System

    Recoil
  • Displacement

    212 cc
  • Net Power

    4.4 kW at 3,600 rpm
  • Net Torque

    12 N·m at 2,500 rpm
  • Pump Set

    2-inch high-lift pump
  • Suction Port

    50 mm (2 inches)
  • Discharge Ports

    1 × 1.5 inches; 2 × 1 inch
  • Maximum Suction Head

    7 m
  • Maximum Total Head

    80 m
  • Maximum Capacity

    16 m³/h (266 L/min)
  • Dimensions

    500 × 395 × 446 mm
  • Net Weight

    29.5 kg

Expert Local Advice

Friendly, experienced & local

Leading Brands

Quality Brands you can trust

Service & Spare Parts

Workshop Parts & Support

Residential & Commercial

Equipment for every job

FAQ

What type of water pump do I need?
The right pump depends on what you need to move, how much water you need to move and how far or high it must travel. A volume or transfer pump is designed to move large quantities of relatively clean water, while a high-pressure pump is better when water must be delivered over greater distances, to higher elevations or through equipment requiring pressure. Trash pumps are designed for dirty water containing suspended solids and debris.
What is the difference between a transfer pump, high-pressure pump and trash pump?
Transfer pumps are primarily designed to move large volumes of clean or relatively clean water efficiently. High-pressure pumps sacrifice some maximum flow in order to generate greater pressure and head, making them useful for applications such as irrigation, long-distance transfer, wash-down and firefighting. Trash pumps use a pump design that allows larger suspended solids and debris to pass through without easily clogging the pump.
How much water flow do I need from a pump?
Flow rate is normally shown in litres per minute and tells you how quickly a pump can move water under particular conditions. Higher flow is useful when filling tanks, draining large areas or moving substantial volumes of water quickly. The important figure is not simply the pump's maximum advertised flow, however, because actual flow decreases as the pump has to lift water higher, push it further or overcome friction in hoses and fittings.
What does total head mean when choosing a water pump?
Total head describes the overall resistance the pump must overcome to move water through your system. It includes the vertical distance the water must be lifted as well as losses caused by the suction line, delivery hose, pipe length, bends, valves and other fittings. This is why a pump that delivers a very high flow at low head may deliver substantially less water when pumping uphill or over a long distance.
How high can a pump lift water from a dam, creek or tank?
The vertical distance between the water surface and the pump is known as suction lift. Portable self-priming centrifugal pumps commonly have a maximum suction lift of around 7 to 8 metres under favourable conditions, but practical performance reduces as suction height increases. For best performance, position the pump as close to the water source and as low as is safely practical, keep the suction hose short and make sure all suction connections are airtight.
What size pump and hose should I use?
Pump sizes such as 1 inch, 2 inch or 3 inch generally refer to the inlet and outlet diameter. Larger hoses can carry substantially more water and reduce friction losses, which can make a major difference over longer distances. A smaller pump is often suitable for portable or lower-flow jobs, while 2-inch and 3-inch pumps are common where larger volumes must be transferred. The best size depends on the required flow, distance, elevation and hose length.
Can I pump dirty water, muddy water or water containing debris?
Only if the pump is designed for it. Standard volume and high-pressure pumps are generally intended for clean or relatively clean water and can be damaged or clogged by excessive sand, stones or debris. Trash pumps are specifically designed to pass suspended solids and are a better choice for construction sites, muddy water and similar applications. Always check the manufacturer's maximum solids specification and use an appropriate suction strainer.
What pump should I use to transfer water from a dam to a storage tank?
Choose the pump according to the vertical rise from the dam to the tank, the horizontal distance, the hose or pipe diameter and how quickly you want the tank filled. A volume pump may be suitable where the distance and elevation are modest, while a high-head or high-pressure pump may be required for a long delivery line or a tank located well above the water source. Larger delivery pipe can also significantly reduce friction loss and improve the amount of water reaching the tank.
Does a self-priming pump still need to be primed before use?
Usually yes. Self-priming means the pump can remove air from the suction line and draw water up once the pump casing has been filled correctly. It does not normally mean the pump should be started completely dry. Before starting, fill the pump casing as specified by the manufacturer, make sure the suction hose and fittings are airtight and ensure the suction strainer is submerged in the water.
Can I use a water pump for firefighting?
For property fire protection, use a pump specifically designed to provide the pressure, flow and reliability required for firefighting rather than assuming that any transfer pump will be suitable. High-pressure fire pumps are designed to maintain useful pressure through firefighting hose and nozzles and may provide multiple outlets. Pump performance, available water supply, hose length, suction conditions and the overall fire-protection setup should all be considered before choosing a system.

Expert Local Advice

Friendly, experienced & local

Leading Brands

Quality Brands you can trust

Service & Spare Parts

Workshop Parts & Support

Residential & Commercial

Equipment for every job